<?xml version="1.0" encoding="UTF-8"?><FDSNStationXML xmlns="http://www.fdsn.org/xml/station/1" schemaVersion="1.2"><Source>SeisComP</Source><Sender>SED</Sender><Created>2026-11-18T13:48:12.126765Z</Created><Network code="8D" startDate="1980-01-01T00:00:00Z" restrictedStatus="open"><Description>Temporary deployments in Switzerland associated with aftershocks, sequences</Description><Identifier type="DOI">10.12686/sed/networks/8d</Identifier><Station code="SGT10" startDate="2013-07-25T00:00:00Z" endDate="2013-11-07T00:00:00Z" restrictedStatus="open"><Latitude>47.4482</Latitude><Longitude>9.3645</Longitude><Elevation>581</Elevation><Site><Name>Unterlaesserhof, SG</Name><Country>Switzerland</Country></Site><CreationDate>2013-07-25T00:00:00Z</CreationDate><Channel code="EHE" startDate="2013-07-25T00:00:00Z" endDate="2013-11-07T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>47.4482</Latitude><Longitude>9.3645</Longitude><Elevation>581</Elevation><Depth>0</Depth><Azimuth>90</Azimuth><Dip>0</Dip><SampleRate>200</SampleRate><SampleRateRatio><NumberSamples>200</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="smi:ch.ethz.sed/Sensor/20150105111036.376426.9"><Type>Lennartz LE-3D-1s</Type><Manufacturer>Lennartz</Manufacturer><Model>LE-3D-1s</Model><SerialNumber>F-407</SerialNumber></Sensor><DataLogger resourceId="smi:ch.ethz.sed/Datalogger/20150105111036.373921.5"><Type>Nanometrics Taurus</Type><Manufacturer>Nanometrics</Manufacturer><Model>Taurus</Model><SerialNumber>2092</SerialNumber></DataLogger><Response><InstrumentSensitivity><Value>160191000</Value><Frequency>10</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHN" startDate="2013-07-25T00:00:00Z" endDate="2013-11-07T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>47.4482</Latitude><Longitude>9.3645</Longitude><Elevation>581</Elevation><Depth>0</Depth><Azimuth>0</Azimuth><Dip>0</Dip><SampleRate>200</SampleRate><SampleRateRatio><NumberSamples>200</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="smi:ch.ethz.sed/Sensor/20150105111036.376426.9"><Type>Lennartz LE-3D-1s</Type><Manufacturer>Lennartz</Manufacturer><Model>LE-3D-1s</Model><SerialNumber>F-407</SerialNumber></Sensor><DataLogger resourceId="smi:ch.ethz.sed/Datalogger/20150105111036.373921.5"><Type>Nanometrics Taurus</Type><Manufacturer>Nanometrics</Manufacturer><Model>Taurus</Model><SerialNumber>2092</SerialNumber></DataLogger><Response><InstrumentSensitivity><Value>160191000</Value><Frequency>10</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHZ" startDate="2013-07-25T00:00:00Z" endDate="2013-11-07T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>47.4482</Latitude><Longitude>9.3645</Longitude><Elevation>581</Elevation><Depth>0</Depth><Azimuth>0</Azimuth><Dip>-90</Dip><SampleRate>200</SampleRate><SampleRateRatio><NumberSamples>200</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="smi:ch.ethz.sed/Sensor/20150105111036.376426.9"><Type>Lennartz LE-3D-1s</Type><Manufacturer>Lennartz</Manufacturer><Model>LE-3D-1s</Model><SerialNumber>F-407</SerialNumber></Sensor><DataLogger resourceId="smi:ch.ethz.sed/Datalogger/20150105111036.373921.5"><Type>Nanometrics Taurus</Type><Manufacturer>Nanometrics</Manufacturer><Model>Taurus</Model><SerialNumber>2092</SerialNumber></DataLogger><Response><InstrumentSensitivity><Value>160191000</Value><Frequency>10</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel></Station></Network></FDSNStationXML>
