<?xml version="1.0" encoding="UTF-8"?><FDSNStationXML xmlns="http://www.fdsn.org/xml/station/1" schemaVersion="1.2"><Source>SeisComP</Source><Sender>SED</Sender><Created>2026-10-15T11:21:11.828968Z</Created><Network code="9S" startDate="2012-01-01T00:00:00Z" endDate="2030-12-31T23:59:59Z" restrictedStatus="open"><Description>Temporary deployments in Switzerland associated with landslides</Description><Identifier type="DOI">10.12686/SED/NETWORKS/XP</Identifier><Station code="OVAIL" startDate="2025-11-12T15:00:00Z" endDate="2030-12-31T23:59:59Z" restrictedStatus="open"><Latitude>46.36535</Latitude><Longitude>6.98702</Longitude><Elevation>1498</Elevation><Site><Name>Ovaille, Plan Falcon, Corbeyrier, VD</Name><Country>Switzerland</Country></Site><CreationDate>2025-11-12T15:00:00Z</CreationDate><Channel code="HH2" startDate="2025-11-12T15:00:00Z" endDate="2030-12-31T23:59:59Z" restrictedStatus="open" locationCode=""><Latitude>46.36535</Latitude><Longitude>6.98702</Longitude><Elevation>1498</Elevation><Depth>0</Depth><Azimuth>90</Azimuth><Dip>0</Dip><SampleRate>200</SampleRate><SampleRateRatio><NumberSamples>200</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><Sensor resourceId="smi:ch.ethz.sed/Sensor/trillium_compact.120s.11472"><Type>Nanometrics Trillium Compact 120s</Type><Manufacturer>Nanometrics</Manufacturer><Model>Trillium Compact 120s</Model><SerialNumber>11472</SerialNumber></Sensor><DataLogger resourceId="smi:ch.ethz.sed/Datalogger/centaur.10992"><Type>Nanometrics Centaur</Type><Manufacturer>Nanometrics</Manufacturer><Model>Centaur</Model><SerialNumber>10992</SerialNumber></DataLogger><Response><InstrumentSensitivity><Value>301720000</Value><Frequency>1</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="HH1" startDate="2025-11-12T15:00:00Z" endDate="2030-12-31T23:59:59Z" restrictedStatus="open" locationCode=""><Latitude>46.36535</Latitude><Longitude>6.98702</Longitude><Elevation>1498</Elevation><Depth>0</Depth><Azimuth>0</Azimuth><Dip>0</Dip><SampleRate>200</SampleRate><SampleRateRatio><NumberSamples>200</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><Sensor resourceId="smi:ch.ethz.sed/Sensor/trillium_compact.120s.11472"><Type>Nanometrics Trillium Compact 120s</Type><Manufacturer>Nanometrics</Manufacturer><Model>Trillium Compact 120s</Model><SerialNumber>11472</SerialNumber></Sensor><DataLogger resourceId="smi:ch.ethz.sed/Datalogger/centaur.10992"><Type>Nanometrics Centaur</Type><Manufacturer>Nanometrics</Manufacturer><Model>Centaur</Model><SerialNumber>10992</SerialNumber></DataLogger><Response><InstrumentSensitivity><Value>301720000</Value><Frequency>1</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="HHZ" startDate="2025-11-12T15:00:00Z" endDate="2030-12-31T23:59:59Z" restrictedStatus="open" locationCode=""><Latitude>46.36535</Latitude><Longitude>6.98702</Longitude><Elevation>1498</Elevation><Depth>0</Depth><Azimuth>0</Azimuth><Dip>-90</Dip><SampleRate>200</SampleRate><SampleRateRatio><NumberSamples>200</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><Sensor resourceId="smi:ch.ethz.sed/Sensor/trillium_compact.120s.11472"><Type>Nanometrics Trillium Compact 120s</Type><Manufacturer>Nanometrics</Manufacturer><Model>Trillium Compact 120s</Model><SerialNumber>11472</SerialNumber></Sensor><DataLogger resourceId="smi:ch.ethz.sed/Datalogger/centaur.10992"><Type>Nanometrics Centaur</Type><Manufacturer>Nanometrics</Manufacturer><Model>Centaur</Model><SerialNumber>10992</SerialNumber></DataLogger><Response><InstrumentSensitivity><Value>301720000</Value><Frequency>1</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel></Station></Network></FDSNStationXML>
